Page view 12
ID Switch is ON or OFF
1 2 3 4 5 6 7 8
Value 1 2 4 8 16 32 64 128
1 ON OFF OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF OFF
3 ON ON OFF OFF OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF OFF OFF
5 ON OFF ON OFF OFF OFF OFF OFF
6 OFF ON ON OFF OFF OFF OFF OFF
7 ON ON ON OFF OFF OFF OFF OFF
8 OFF OFF OFF ON OFF OFF OFF OFF
9 ON OFF OFF ON OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF
11 ON ON OFF ON OFF OFF OFF OFF
12 OFF OFF ON ON OFF OFF OFF OFF
13 ON OFF ON ON OFF OFF OFF OFF
14 OFF ON ON ON OFF OFF OFF OFF
15 ON ON ON ON OFF OFF OFF OFF
16 OFF OFF OFF OFF ON OFF OFF OFF
..... ..... ..... ..... ..... ..... ..... ..... .....
255 ON ON ON ON ON ON ON ON
7
Changing Protocol Information
English
To calculate the ID, add up the Value shown for each switch that is ON.
EXAMPLE: If switches #1, #2, and #3 are ON, ID = 1 + 2 + 4 = 7.
8
Changing Protocol Information
3.3 SETTING THE CAMERA PROTOCOL AND BAUD
RATE
Protocol and baud rate are set using switches 1&2 on the smaller DIP
switch panel. See the table below.
Protocol and Baud Rate Switches
1 2 Protocol/Baud Rate
OFF OFF Pelco-D 2400
ON OFF Pelco-D 9600
OFF ON Pelco-P 4800
ON ON Pelco-P 9600
Switches 3 & 4 are for manufacturer use only and
should always be set to OFF.